SPECIFY. COMPARE. DOWNLOAD WITH CONFIDENCE.

Engineering Pipe Datasheets & Technical Specifications

GEOLUR provides technical datasheet guidance for PVC/PVC-U monitoring pipes, ABS inclinometer casings, PE/HDPE engineering pipes and custom perforated pipes, helping engineers specify, compare and request project-ready products.

Technical Datasheet Resource

A datasheet should answer the engineering questions before the pipe reaches site.

This GEOLUR resource explains how to read, compare and request datasheets for PVC/PVC-U monitoring pipes, ABS inclinometer casings, PE/HDPE engineering pipes and custom perforated pipes. It is designed for engineers, procurement teams, contractors and consultants who need technical information for product selection and submittal review.

Selection

Critical parameters

Material, dimensions, connection, mechanical limits and functional geometry should be visible enough to judge suitability.

Comparison

Compare like with like

The same nominal description can hide different ID, wall, joint, groove, slot or installation limits.

Submittal

Data is not approval

A datasheet supports review; final acceptance depends on the project specification, approved submittal and responsible engineer.

GEOLUR principle: disclose the parameters that control real installation and monitoring performance without transferring another manufacturer’s values or certificates to GEOLUR products.

Datasheet Library

Four product families. Four different technical data priorities.

This page is the resource hub. Exact model- or configuration-specific values should remain on the relevant GEOLUR product page or controlled PDF datasheet.

PVC / PVC-U

Monitoring & Well Pipes

Standpipes, piezometers, groundwater monitoring, recharge and dewatering wells.

PVC products →
ABS

Inclinometer Casings

Borehole/horizontal inclinometers, walls, slopes, tunnels and excavations.

ABS casings →
PE / HDPE

Engineering Pipes

Deep dewatering, recharge/relief, pumping, environmental and corrosive environments.

PE / HDPE products →
Custom

Perforated Pipes

Project-specific slot/hole geometry, rows, pitch, orientation and screened length.

Perforated pipes →

How to Read a Datasheet

Do not stop at diameter and material.

A useful datasheet connects the product name to compatibility, installation and service conditions. Check whether a value describes the actual offered configuration or only a wider product family.

FieldWhy it mattersReview question
MaterialStiffness, impact, temperature, chemicals, joining.Is the stated material/grade the project requirement?
OD / ID / WallBorehole clearance, probe/pump access, coupling fit.Nominal or actual dimensions? What tolerance?
ConnectionAssembly, alignment, seal, maximum OD and tensile behaviour.What joint and accessories are supplied?
Mechanical dataDeep installation may depend on collapse/tensile/pressure limits.Does the value apply to pipe, screen, coupling or joint?
Functional geometryGrooves, slots and perforations affect measurement/hydraulics.What geometry and tolerance are controlled?
Certificate scopeCertificates are product-specific.Does it apply to the exact offered item?

PVC / PVC-U Datasheets

For monitoring and well pipe, hydraulic geometry and installation strength both matter.

A PVC/PVC-U datasheet should identify plain casing versus screen and expose the dimensions, connection and screen geometry needed for groundwater monitoring, recharge or dewatering.

  • Material / grade or formulation
  • Actual OD and ID
  • Wall thickness and length
  • Plain or screened section
  • Slot width / tolerance
  • Open area where required
  • Joint / coupling type
  • Maximum joint OD
  • Collapse/depth data if applicable
  • Joint tensile data if applicable
  • Temperature / chemical limits
  • Caps and accessories
Boode’s published well-screen documentation is a useful completeness benchmark because it combines dimensions, connection types, slot sizes, collapse resistance, joint loads and applications. Those values remain Boode-specific.

ABS Inclinometer Casing Datasheets

The groove system is a measurement interface — not decorative geometry.

ABS casing should be documented as part of the inclinometer measurement system. Internal guide grooves orient the probe or in-place sensors; spiral/twist, casing dimensions and coupling geometry can therefore affect measurement and installation.

Geometry

OD, ID, length, four guide grooves/keyways, groove orientation and spiral/twist criterion.

Joint system

Standard, fixed, push-fit or telescopic coupling; dimensions, alignment/sealing and telescoping range.

Mechanical data

Collapse, bend, tensile, torque and temperature data where available for the exact system.

Soil Instruments’ current C18 datasheet publishes ABS material, groove spiral, collapse, bend, tensile, torque, temperature and casing/coupling dimensions. This is a benchmark for disclosure depth, not a GEOLUR specification.

PE / HDPE Datasheets

Material grade, dimensional series and joining method must be read together.

PE/HDPE engineering pipe may suit groundwater-control, environmental or corrosive conditions, but the datasheet must identify the actual pipe system. A pressure-pipe standard should not be assumed to cover every screen or custom-perforated configuration.

Pipe definition

Material grade/type, OD, wall or SDR/series, length and intended duty.

Joining

Butt fusion, electrofusion, threaded or mechanical joints require different equipment and field QA/QC.

Evidence

If EN, ISO, FM, EN 10204 or another requirement applies, verify the exact certificate/product scope.

AGRU documentation illustrates mature QA through incoming-material, production and finished-product inspection, product marking and inspection certificates for specified products. It is a documentation benchmark, not a GEOLUR certification claim.

Custom Perforated Pipe Data

For a custom screen, the approved drawing is part of the datasheet.

A generic PDF cannot fully define project-specific perforation. GEOLUR recommends pairing the base-pipe datasheet with a controlled fabrication drawing.

  • Base-pipe material / reference
  • OD / ID / wall / length
  • Slot or hole geometry
  • Opening tolerance
  • Number of rows
  • Longitudinal / circumferential pitch
  • Orientation
  • Perforated interval
  • Open area if required
  • Unperforated end lengths
  • Deburring / finish
  • Drawing number / revision

Datasheet Comparison

A fast comparison matrix for engineers and procurement teams.

ParameterPVC / PVC-UABSPE / HDPECustom Perforated
Primary functionWell casing/screenProbe/sensor guideWell/engineering pipeHydraulic opening
Critical geometryOD/ID/wall + slotOD/ID + groove/spiralOD/wall/SDRBase pipe + opening pattern
Connection focusProfile, seal, strengthAlignment/movementWeld/thread/mechanicalBase-pipe joint
Extra documentScreen scheduleInstallation/manual dataJoining procedure if relevantFabrication drawing

Datasheet QA/QC

A technical PDF is useful only when it matches the product being supplied.

GEOLUR, operated by GeoOrigin Engineering Limited, should connect each final datasheet or project submittal to an identifiable product/configuration and keep custom revisions controlled.

Revision control

Document number, revision and issue date.

Product identity

Material, size/configuration and relevant product/drawing reference.

Units & test basis

Clear units and whether values are nominal, typical, minimum or test-derived.

Certificate scope

Confirm certificates apply to the offered item.

Deviation control

Show deviations rather than silently substituting a nearby product.

Custom drawing

Reference the fabrication drawing revision in commercial and QA documents.

Regional Engineering Context

Datasheet priorities change with project conditions.

The same polymer pipe may be used in different environments. Review datasheet information against installation conditions, not only logistics.

Southeast Asia

Soft ground & groundwater control

Deep excavations and dewatering can make alignment, well depth, collapse behaviour and joint reliability important.

Europe

Traceability & standards

Environmental and infrastructure work may require stronger product identity, certificate scope and controlled documentation.

Middle East

Heat, UV & salinity

Temperature, storage, UV, chemical conditions, pipe length and packing can affect selection.

Regional references do not imply a local GEOLUR certification, warehouse or inventory. Confirm availability and compliance in the specific quotation.

Request Project Data

Tell GEOLUR what must be proven on paper before you buy.

Send the application, dimensions, quantity, specification and mandatory standard/certificate. GEOLUR can identify available product data and flag items requiring confirmation.

  • Product family / application
  • Country / delivery destination
  • OD / ID / wall / SDR
  • Length / quantity
  • Connection / coupling
  • Slot / perforation / groove
  • Mechanical criteria
  • Temperature / chemical environment
  • Required standards / certificates
  • Drawing / BOQ revision

Frequently Asked Questions

Engineering pipe datasheet FAQs.

Does a datasheet prove project approval?

No. It describes a product. Project approval depends on the specification, submittal requirements and responsible project parties.

What should an ABS casing datasheet show?

Material, OD/ID, length, guide-groove geometry, joint/coupling information and relevant spiral/twist or mechanical data.

Why does PVC well screen need extra data?

The screen is also a hydraulic interface, so slot geometry, open area, wall, connection and mechanical behaviour can matter.

Is SDR enough for HDPE?

No. Also define material/type, OD, joining method, configuration, application and project-specific requirements.

How should custom perforated pipe be documented?

Use a base-pipe datasheet plus a controlled drawing showing openings, rows, pitch, orientation, interval, tolerances and revision.

Can competitor values be used as GEOLUR specifications?

No. Competitor data shows what parameters can be disclosed; their values and certificates remain specific to their products.

Technical Enquiry

Need the right datasheet for an actual project?

Send GEOLUR your BOQ, specification, drawing or required pipe parameters. We can align the technical enquiry with PVC/PVC-U monitoring pipes, ABS inclinometer casings, PE/HDPE engineering pipes or custom perforated pipe systems.

Scroll to Top